Delta Electronics ASDA-AB manual Aout, Pulse Output Polarity Setting Communication Addr H, DOF1

Models: ASDA-AB

1 357
Download 357 pages 17.54 Kb
Page 144
Image 144

Chapter 6 Control Modes of OperationASDA-AB Series

Example: P0-03 = 01(CH1 is speed analog output)

Motor rotation speed = (Max. rotation speed × V1/8) × P1-04/100, when the output voltage value of CH1 is V1.

P1 - 03

AOUT

Pulse Output Polarity Setting

Communication Addr.: 0103H

 

 

 

Default: 0

Related Section:

Applicable Control Mode: P/S/T

Section 3.3.3

Unit: N/A

 

Range: 0 ~ 1

 

Settings:

 

Monitor analog output polarity

A=0: MON1(+), MON2(+)

A=1: MON1(+), MON2(-)

A

A=2: MON1(-), MON2(+)

B

A=3: MON1(-), MON2(-)

 

not used

Pulse output polarity

B=0: Forward output

B=1: Reverse output

P1 - 04

Analog Monitor Output Proportion 1 (CH1)

Communication Addr.: 0104H

 

 

Default: 100

Related Section:

Applicable Control Mode: P/S/T

Section 6.4.4

Unit: % (full scale)

 

Range: 0 ~ 100

 

P1 - 05

Analog Monitor Output Proportion 2 (CH2)

Communication Addr.: 0105H

 

 

Default: 100

Related Section:

Applicable Control Mode: P/S/T

Section 6.4.4

Unit: % (full scale)

 

Range: 0~100

 

P4 - 20

DOF1

Analog Monitor Output Drift Adjustment (CH1)

Communication Addr.: 0414H

 

 

 

Default: Factory setting

Related Section:

Applicable Control Mode: P/S/T

Section 6.4.4

Unit: mV

 

 

Range: -800~800

This parameter cannot be reset.

Revision January 2009

6-41

Page 144
Image 144
Delta Electronics ASDA-AB manual Aout, Pulse Output Polarity Setting Communication Addr H, DOF1