P2 - 33▲

 

 

Chapter 7 Servo ParametersASDA-AB Series

 

 

 

 

 

INF

Easy Setting of Input Filter

 

Communication Addr.: 0221H

 

 

 

 

 

 

Default: 0

 

 

Related Section:

Applicable Control Mode: ALL

 

Section 6.3.6

Unit: N/A

 

 

 

 

Range: 00 ~ 19

Settings:

A

B

not used

A: Speed selection

A=0

Low speed

A=9 High speed

B=1: Enable this function

P2 - 34

SDEV

Overspeed Warning Condition

Communication Addr.: 0222H

 

 

 

Default: 5000

Related Section: N/A

Applicable Control Mode: S

Unit: r/min

Range: 1 ~ 5000

Settings:

This parameter is used to set the over speed condition of the drive fault code. (See P0-01)

P2 - 35

PDEV

Excessive Error Warning Condition

Communication Addr.: 0223H

 

 

 

Default: 30000

Related Section: N/A

Applicable Control Mode: Pt, Pr

Unit: pulse

Range: 1 ~ 30000

Settings:

This parameter is used to set the excessive error condition of the drive fault code (See P0-01) . As for the proportion value setting of position excessive error warning condition, please refer to P2-63.

Revision January 2009

7-63