The users can select the adequate regenerative resistors according to the allowable frequency by referring to the table below:
Allowable frequency when the servo motor run without load (times/min)
ECMA Series400W (60mm)
04 8608 21517
400W
(80mm)
04
3279
8765
( ) : motor frame size, unit is in millimeters.
Regenerative Resistors
BR400W040
BR1K0W020
m = load/motor inertia ratio

Chapter 6 Control Modes of OperationASDA-AB Series

For example:

When external load torque is a +70% rated torque and rotation speed reaches 3000r/min, if using 400W servo drive (rated torque: 1.27Nt-m), then the users need to connect a external regenerative resistor which power is 2 x (0.7 x 1.27) x (3000 x 2 x π/ 60) = 560W, 40Ω.

„Simple Calculation Method

The users can select the adequate regenerative resistors according to the allowable frequency required by actual operation and the allowable frequency when the servo motor runs without load. The allowable frequency when the servo motor run without load is the maximum frequency that can be operated during continuous operation when servo motor accelerate from 0r/min to rated speed and decelerate from rated speed down to 0r/min. The allowable frequencies when the servo motor run without load are summarized in the following table.

Allowable frequency when the servo motor run without load (times/min)

 

 

100W

200W

300W

400W

400W

500W

600W

750W

 

 

ECMA Series

(60mm)

(80mm)

 

 

 

 

 

 

 

 

 

 

 

01

02

03

04

04

05

06

07

 

 

Allowable Frequency

-

-

-

1275

519

43

41

319

 

 

(times/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

900W

1.0kW

1.0kW

1.5kW

2.0kW

2.0kW

2.0kW

 

 

 

ECMA Series

(100mm)

(130mm)

(100mm)

(130mm)

(180mm)

 

 

 

 

 

 

 

 

 

09

10

10

15

20

20

20

 

 

 

Allowable Frequency

31

137

42

31

82

24

10

 

 

 

(times/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

( ) : motor frame size, unit is in millimeters.

When the servo motor runs with load, the allowable frequency will change according to the changes of the load inertia and rotation speed. Use the following equation to calculate the allowable frequency.

Allowable frequency =

Allowable frequency when serv o motor run without load

x

Rated s peed

2 times

 

 

m + 1

Operating speed

 

mi n.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision January 2009

6-39

Page 142
Image 142
Delta Electronics ASDA-AB manual „ Simple Calculation Method