Chapter 7 Servo ParametersASDA-AB Series

7.3Detailed Parameter Listings

Group 0: P0-xx Monitor Parameters

 

P0 - 00

 

VER

Firmware Version

Communication Addr.: 0000H

 

 

 

 

 

 

 

 

 

Default: Factory setting

Related Section: N/A

 

 

 

Applicable Control Mode: ALL

 

 

 

 

Unit: N/A

 

 

Range: N/A

P0 - 01

ALE

Drive Fault Code

 

Communication Addr.: 0001H

 

 

 

 

Default: Factory setting

 

Related Section:

Applicable Control Mode: ALL

 

Chapter 10

Unit: N/A

 

 

 

Range: 00 ~ 23

 

 

Settings:

 

 

 

01: Overcurrent

21: DSP to MCU command write-in error

02: Overvoltage

22: Input power phase loss

03: Undervoltage

23: Pre-overload warning

04: Z Pulse shift

 

 

05:Regeneration error

06:Overload

07:Overspeed

08:Abnormal pulse control command

09:Excessive deviation

10:Watch dog fault

11:Position detector fault

12:Adjustment error

13:Emergency stop

14:Reverse limit error

15:Forward limit error

16:IGBT temperature error

17:Memory error

18:DSP communication error

19:Serial communication error

20:Serial communication time out

7-20