Chapter 7 Servo ParametersASDA-AB Series

 

P3 - 06

 

SDI

Digital Input Communication Function

Communication Addr.: 0306H

 

 

 

 

 

 

 

 

 

Default: 0

 

Related Section:

 

 

 

Applicable Control Mode: ALL

P4-07, Section 8.2

 

 

 

Unit: N/A

 

 

Range: 0~FFFF

Settings:

The setting of this parameter determines how the Digital Inputs (DI) accept commands and signals. If the Digital Input Contact Control parameter for the DI 1 ~ DI 8 is set to "0", command is external, and via CN1; if it is set to "1" the DI signal is via communication.

Bit0 ~ Bit 7 corresponds with DI1 ~ DI8. The least significant bit (Bit0) shows DI1 status and the most significant bit (Bit7) shows DI8 status. The new DI9 ~ DI16 for software communication corresponds with CTRG / POS0 / POS1 / POS2 / ARST / SHOM / JOGU / JOGD these signals.

The Digital Input Control Contact parameter, P3-06 also works in conjunction with the Multi Function Digital Input parameter P4-07 which has several functions. Please see section 8.2 for details.

P3 - 07

CDT

Communication Response Delay Time

Communication Addr.: 0307H

 

 

 

Default: 0

 

Related Section: N/A

Applicable Control Mode: ALL

Unit: 0.5ms

Range: 0~255

Settings:

This parameter is used to delay the communication time that servo drive responds to host controller (external controller).

7-80

Revision January 2009

Page 229
Image 229
Delta Electronics ASDA-AB manual Sdi, Digital Input Communication Function Communication Addr H, Cdt