Delta Electronics ASDA-AB manual Adr, Brt, Transmission Speed Communication Addr H

Models: ASDA-AB

1 357
Download 357 pages 17.54 Kb
Page 226
Image 226

 

 

 

 

Chapter 7 Servo ParametersASDA-AB Series

Group 3: P3-xx Communication Parameters

 

 

 

 

 

 

 

 

 

 

P3 - 00

 

ADR

Communication Address Setting

 

Communication Addr.: 0300H

 

 

 

 

 

 

 

 

 

 

Default: 1

 

 

Related Section:

 

 

Applicable Control Mode: ALL

 

Section 8.2

 

 

Unit: N/A

 

 

 

 

Range: 1~254

Settings:

If the AC servo drive is controlled by RS-232/485/422 communication, each drive (or device) must be uniquely identified and addressed between 1 and 254. Access to program this number is via parameter P3-00.

One servo drive only can set one address. If the address is duplicate, there will be a communication fault.

NOTE

1)When the address of host (external) controller is set to 0, it is with broadcast function. Then, the servo drive will receive from host (external) controller only and will not respond to host (external) controller no matter the address is matching or not.

2)When the address of host (external) controller is set to 255, it is with auto-respond function. Then, the servo drive will receive from and respond to host (external) controller both no matter the address is matching or not.

P3 - 01

BRT

Transmission Speed

Communication Addr.: 0301H

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: ALL

Section 8.2

Unit: bps

 

 

Range: 0~5

Settings:

0:Baud rate 4800 (data transmission speed: bits / second)

1:Baud rate 9600 (data transmission speed: bits / second)

2:Baud rate 19200 (data transmission speed: bits / second)

3:Baud rate 38400 (data transmission speed: bits / second)

4:Baud rate 57600 (data transmission speed: bits / second)

5:Baud rate 115200 (data transmission speed: bits / second)

This parameter is used to set the desired transmission speed between the computer and AC servo drive. Users can set this parameter and control transmission speed to reach the maximum baud rate of 115200 bps.

Revision January 2009

7-77

Page 226
Image 226
Delta Electronics ASDA-AB manual Adr, Brt, Transmission Speed Communication Addr H