Chapter 12 Application Examples ASDA-AB Series

 

 

 

 

Parameter

Communication

Parameter Description

 

Address

 

 

 

 

P1-50

0132H

Homing Offset Rotation Number

 

 

 

 

 

P1-51

0133H

Homing Offset Pulse Number

 

 

 

Total homing offset pulse number =P1-50 x 10000 + P1-51

 

 

 

 

 

P1-55

0137H

Maximum Speed Limit

 

 

 

 

 

P2-36

0224H

Moving Speed Setting of 1st Position

 

 

 

Maximum feed step speed

 

 

 

(When speed is above 3000r/min, please set P1-55 to a proper

 

 

 

value)

 

 

 

 

 

P2-44

022CH

Digital Output Mode Setting

 

 

 

0: General output mode

 

 

 

1: Combination output mode

 

 

 

 

 

„Relevant Parameters Description, cont.

Parameter

Communication

Parameter Description

Address

 

 

P2-45

022DH

Combination Output Signal Delay Time [UNIT: 4msec]

 

 

Output signal will hold delay time when position command is

 

 

completed.

 

 

 

P2-46

022EH

Feed Step Number

 

 

Range: 2~32

 

 

 

P2-47

022FH

Position Deviation Clear Delay Time [UNIT: 20msec]

 

 

This function is disabled when its setting value is set to 0.

 

 

 

P2-51

0233H

Internal Servo ON setting

 

 

 

„Digital I/O Signal Setting

DI Signal

Parameter Setting

Explanation

DI1 (INDEX0)

P2-10 = 128

Feed step selection input 0

 

 

 

DI2 (INDEX1)

P2-11 = 129

Feed step selection input 1

 

 

 

DI3 (INDEX2)

P2-12 = 130

Feed step selection input 2

 

 

 

DI4 (INDEX3)

P2-13 = 131

Feed step selection input 3

 

 

 

DI5 (ORGP)

P2-14 = 124

Reference “Home” sensor

 

 

 

DI6 (SON)

P2-15 = 101

Servo ON (when the setting value is 137, it is

manual operation function.)

 

 

(MDP0)

P2-15 = 35 (contact “b”)

Manually continuous operation

 

 

 

(MDP1)

P2-15 = 36 (contact “b”)

Manually single step operation

 

 

 

DI7 (MD0)

P2-16 = 33 (contact “b”)

Feed step mode input 0

 

 

 

DI8 (MD1)

P2-17 = 34 (contact “b”)

Feed step mode input 1

 

 

 

Revision January 2009

12-15

Page 312
Image 312
Delta Electronics ASDA-AB manual „ Relevant Parameters Description, „ Digital I/O Signal Setting