Chapter 7 Servo ParametersASDA-AB Series

P1 - 45▲

GR2

Electronic Gear Ratio (Denominator)

Communication Addr.: 012DH

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: Pt, Pr

Section 6.3.6

Unit: Pulse

Range: 1 ~ 32767

Settings:

Electronic gear denominator setting.

It is recommended to set electronic gear ratio when the servo drive is Off. As the wrong setting may cause motor to run chaotically (out of control) and it may lead to personnel injury, therefore, ensure to observe the following rule when setting P1-44, P1-45.

The electronic gear ratio setting (Please also see P1-44, P2-60 ~ P2-62):

Pulse input

f1

f1: Pulse input

Position N command

MN f2 = f1 x M

f2: Position command

N:Numerator 1, 2, 3, 4, the setting value of P1-44 or P2-60 ~ P2-63

M:Denominator, the setting value of P1-45

The electronic gear ratio setting range must be within: 1/50<N/M<200.

7-44

Revision January 2009

Page 193
Image 193
Delta Electronics ASDA-AB manual GR2