Operation 5. Troubleshooting

5.Troubleshooting

Display panel is blank

-The Controller supplies DC24V. Check that the Controller is ON.

-Check that the Controller is connected to the TP/OP connector of the Controller properly.

An Error code appears and the Robot does not operate normally

- Please refer to the error code indicated in the Controller manual.

Robot does not move by pressing the Jog key

-Execute the Motor On command to energize the Robot motor. (Refer to Motor On in the SPEL+ Language Reference)

-Energize the Robot motor.

(Refer to SLock in the SPEL+ Language Reference)

-Short jog distance may be selected.

Check the value in the [Jog Distance] screen and change the setting to long distance if needed.

(Refer to Operation 2.3 Changing Jog Distance Data)

Operation mode does not switch from TEACH mode to AUTO mode

- Send the latch release input signal to release the latch status.

If the condition does not change after performing the countermeasure above, the unit may have suffered a breakdown.

Please contact the service center or the manufacturer.

100

TP1 Rev.5

Page 110
Image 110
Epson TP1 manual Troubleshooting, Display panel is blank, Robot does not move by pressing the Jog key