Chapter 9 Specifications

Module Specifications

Module Specifications

HP 34901A, 34902A, 34908A, 34903A, 34904A

 

 

 

 

Multiplexer

 

Actuator

Matrix

 

 

 

 

 

 

 

 

General

 

 

34901A

34902A

34908A

34903A

34904A

Number of Channels

 

20+2

16

40

20

4x8

 

 

 

2/4 wire

2/4 wire

1 wire

SPDT

2 wire

 

 

 

 

 

 

 

Connects to Internal DMM

 

Yes

Yes

Yes

No

No

 

 

 

 

 

 

 

 

Scanning Speed

 

 

60 ch/s

250 ch/s

60 ch/s

 

 

Open/Close Speed

 

120/s

120/s

70/s

120/s

120/s

Maximum Input

 

 

 

 

 

 

 

Voltage (dc, ac rms)

 

300 V

300 V

300 V

300 V

300 V

 

 

 

 

 

 

 

Current (dc, ac rms)

 

1 A

50 mA

1 A

1 A

1 A

Power (W, VA)

 

 

50 W

2 W

50 W

50 W

50 W

Isolation (ch-ch, ch-earth)

dc, ac rms

300 V

300 V

300 V

300 V

300 V

 

 

 

 

 

 

 

 

DC Characteristics

 

 

 

 

 

 

 

Offset Voltage [1]

 

 

< 3 μV

< 6 μV

< 3 μV

< 3 μV

< 3 μV

Initial Closed Channel R [1]

 

< 1Ω

< 1Ω

< 1Ω

< 0.2Ω

< 1Ω

Isolation (ch-ch, ch-earth)

 

> 10 GΩ

> 10 GΩ

> 10 GΩ

> 10 GΩ

> 10 GΩ

 

 

 

 

 

 

 

 

AC Characteristics

 

 

 

 

 

 

 

Bandwidth

 

 

10 MHz

10 MHz

10 MHz

10 MHz

10 MHz

Ch-Ch Cross Talk (dB) [2]

10 MHz

-45

-45

-18 [3]

-45

-33

Capacitance

 

HI to LO

< 50 pF

< 50 pF

< 50 pF

< 10 pF

< 50 pF

 

 

 

 

 

 

 

 

Capacitance

 

LO to Earth

< 80 pF

< 80 pF

< 80 pF

< 80 pF

< 80 pF

Volt-Hertz Limit

 

 

108

108

108

108

108

Other

 

 

 

 

 

 

 

T/C Cold Junction Accuracy [1] (typical)

0.8 °C

0.8 °C

0.8 °C

 

 

Switch Life

No Load (typical)

100M

100M

100M

100M

100M

Switch Life

Rated Load (typical) [4]

100k

100k

100k

100k

100k

Temperature

 

Operating

 

All Modules – 0 °C to 55 °C

 

 

 

 

 

 

 

Temperature

 

Storage

 

All Modules – -20 °C to 70 °C

 

 

 

 

 

 

Humidity (non-condensing)

 

 

All Modules – 40 °C / 80% R.H.

 

[1]Errors included in the DMM measurement accuracy specifications

[2]50Ω source, 50Ω load

[3]Isolation within channel 1 to 20 or 21 to 40 banks is -40 dB

[4]Applies to resistive loads only

4099