Item | Description |
| Set the IDs of the VLANs that the selected ports are to be assigned to or removed |
VLAN IDs | from. This item is available when the Untagged, Tagged, or Not A Member option |
| is selected in the Select membership type area. |
|
|
| Set the link type of the selected ports, which can be access, hybrid, or trunk. |
Link Type | This item is available when the Link Type option is selected in the Select |
| membership type area. |
|
|
PVID | Set the PVID of the selected ports. |
| If you select Delete, you restore the PVID to VLAN 1. |
| |
Delete | This item is available when the PVID option is selected in the Select membership |
| type area. |
|
|
Return to VLAN configuration task list (approach II).
VLAN configuration exampleNetwork requirements
As shown in a:
∙Trunk port GigabitEthernet 1/0/1 of Switch A is connected to trunk port GigabitEthernet 1/0/1 of Switch B.
∙The PVID of GigabitEthernet 1/0/1 is VLAN 100.
∙GigabitEthernet 1/0/1 permits packets of VLAN 2, VLAN 6 through VLAN 50, and VLAN 100 to pass through.
a.Network diagram for VLAN configuration
Configuration procedure
Table 44 Configure Switch A
# Configure GigabitEthernet 1/0/1 as a trunk port and configure VLAN 100 as its PVID.
Select Device Port Management from the navigation tree and click the Setup tab to enter the page shown in b.
143