Item |
| Description |
| Interval | Set the sampling interval. |
|
|
|
Sample |
| Set the sampling type, including: |
| ∙ | |
Item | Sample Type | when the sampling time is reached. |
| ||
|
| ∙ |
|
| during the sampling interval when the sampling time is reached. |
|
|
|
Owner |
| Set the owner of the alarm entry. |
|
|
|
|
| Select whether to create a default event. |
|
| The description of the default event is default event, the action is |
| Create Default | and the owner is default owner. |
| If there is no event, you can select to create the default event. And when the value | |
| Event | |
|
| of the alarm variable is higher than the alarm rising threshold or lower than the |
|
| alarm falling threshold, the system will adopt the default action, that is, |
|
| |
|
|
|
| Rising | Set the alarm rising threshold. |
| Threshold | |
Alarm |
| |
|
| |
| Set the action that the system will take when the value of the alarm variable is | |
|
| |
| Rising Event | higher than the alarm rising threshold. |
|
| If the Create Default Event check box is selected, this option is not configurable. |
|
|
|
| Falling | Set the alarm falling threshold. |
| Threshold | |
|
| |
|
|
|
|
| Set the action that the system will take when the value of the alarm variable is |
| Falling Event | lower than the alarm falling threshold. |
|
| If the Create Default Event check box is selected, this option is not configurable. |
|
|
|
Return to RMON alarm configuration task list.
Displaying RMON statistics information
Select Device RMON from the navigation tree to enter the page of the Statistics tab, as shown in a. Click the icon of a statistics entry to enter the page as shown in a, which displays all statistics items on the current interface.
104