Sample File modem_z0.cfg

#

#COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP Z0

#FUNCTIONS: Modem configuration file for some early Hayes* compatible modems.

#This example uses the ATZ0 reset command to choose the factory defaults.

#This setup is recommended for modems that will respond to the ATZ0 command

#and which do not respond to the extended (&) commands. Refer to your modem

#manual.

#

#* Trademark of Hayes Microcomputer Products, Inc.

#(C) COPYRIGHT International Business Machines Corp. 1996

#All Rights Reserved

#Licensed Materials - Property of IBM

#

#US Government Users Restricted Rights - Use, duplication or

#disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

#If the modem has configuration switches, they should be set to the

#factory default settings.

ICDelay 1

 

 

 

DefaultTO 10

 

 

 

CallDelay 120

 

 

 

#

AT

Attention Code

,

Inserts delay in dialing commands

#

Z0

Reset. Restore Profile 0 Q0

Turn on responses

#

E0

Turn echo off

Q1

Turn off responses

#

V0

Use numeric responses

S0=0

Automatic answer inhibit

# +++

Escape to command mode

S0=2

Answer on second ring

#

H0

Hang-up

X0=0

Limit modem

response codes

#

 

 

T =

Tone mode.

When used as T\r, it is a

#

 

 

 

no op to maintain program synchronization

#

 

 

 

when modem may/will echo the commands.

#

 

 

 

 

 

#

%N

Call-Out phone number

%P

Paging phone number

#%S Modem speed (available to users)

#Following are common responses from a wide range of modems:

#16, 15, 12, 10, 5 and 1 are connection responses. Add others as required.

#7=busy; 6=no dial tone; 4=error; 3=no carrier; 2=ring; 0=OK

#

# PROGRAMMING NOTE: No blanks between double quote marks (").

condout:

send "ATZ0Q0T\r"

# Reset modem.

Select profile 0

 

ignore "0\r" or "OK\r\n" timeout 2

# Ignore modem

response.

 

send "ATE0T\r"

# Initialize modem: Echo OFF,

 

expect "0\r" or "OK\r\n" timeout 2

#

Enable

responses (Numeric),

 

send "ATQ0V0X0T\r"

#

Limit response codes.

 

expect "0\r" timeout 2

# Confirm

commands successful.

 

send "ATS0=0\r"

# Set AutoAnswer OFF

 

expect "0\r" timeout 2

# Confirm

command successful.

 

done

 

 

 

 

connect:

send "ATDT%N\r"

# Tone dialing

command.

 

 

# %N from

Call

Home setup.

# Expect a connection response.

expect "16\r" or "15\r" or "14\r" or "12\r" or "10\r" or "5\r" or "1\r" busy "7\r" timeout 60

done

retry:

send "A/"

# Repeat the previous command.

# Expect a connection response.

Appendix F. Modem Configurations 197