1.Bring-up failure

2.Run-time non-recoverable failure

3.Run-time recoverable failure

4.Group integrity failure

5.Non-repeat-gardable error. The resource may be reconfigured on the next boot.

An error status of 00 (for example, 3.16(00)) indicates that the memory DIMM has not had any errors logged against it by the service processor.

To change the memory configuration, select the number of the memory DIMM. The memory DIMM state will change from configured to deconfigured or from deconfigured to configured.

In the previous example menu, each line shows two DIMMs and indicates whether they are configured.

To enable or disable Memory Repeat Gard, use menu option 77 of the Processor Configuration/Deconfiguration Menu.

The failure history of each DIMM is retained. If a DIMM with a history of failures is brought back online by disabling Repeat Gard, it remains online if it passes testing during the boot process. However, if Repeat Gard is enabled, the DIMM is taken offline again because of its history of failures.

vPower Control Network Utilities Menu

POWER CONTROL NETWORK UTILITIES MENU

1.Lamp Test for all Operator Panels

2.Display I/O Type

3.Change I/O Type

98.Return to Previous Menu

0>

±Lamp Test for All Operator Panels

Selecting this option tests the media drawer operator panel's indicators by causing them to blink on and off for approximately 30 seconds.

±Display I/O Type

This option is not available on this system.

±Change I/O Type

Use this option to change the I/O type after a service action or configuration change, if the I/O type is incorrect. If this option is chosen, you will be asked to make the following entries:

1.For the I/O drawer address, type 1.

2.For the I/O type, type A3.

Chapter 3. Using the Service Processor 49