Step 4

This step attempts to load the standalone diagnostics.

1.Turn off the power.

2.Turn on the power.

3.Insert the diagnostic CD-ROM into the CD-ROM drive.

4.If the keyboard indicator displays, press 5 on the directly attached or ASCII keyboard, to indicate that diagnostics are to be loaded.

5.Enter any requested passwords.

6.Follow any instructions to select a console.

7.Wait until the diagnostics load or the system appears to stop.

Did the diagnostics load?

NO

Go to ªStep 5º.

YES

Go to ªStep 6º on page 168.

Step 5

Starting at the top of the following table, find your symptom and follow the instructions given in the Action column.

Symptom

Action

 

 

The power LED does not come on, or comes

Check the power cable to the outlet. Check the

on and does not stay on.

circuit breakers and check for power at the

 

outlet.

 

Ensure that the room temperature is within 60 -

 

90°F.

 

If you do not find a problem, record error code

 

M0PS0000 and report the problem to the

 

service organization.

 

 

The system appears to be stopped and No

Processor POST failure. Report error code

beep was heard from the system unit.

M0CPU000.

 

 

The system appears to be stopped and No

No good memory could be found. Report error

beep was heard from the system unit. E122,

code M0MEM000.

E123, or E124 is displayed on the operator

 

panel display.

 

 

 

The system appears to be stopped. A beep was

No good memory could be found. Report error

heard from the system unit.

code M0MEM001.

 

 

The diagnostics are loaded and there was No

Record error code M0SPK001.

beep heard from the system unit during the IPL

 

sequence.

 

 

 

The system stops with the Diagnostic Operating

Go to ªStep 6º on page 168.

Instructions displayed.

 

 

 

The diskette LED is blinking rapidly, or E1EA or

The flash EPROM data is corrupted. Run the

E1EB is displayed on the operator panel.

recovery procedure for the flash EPROM.

 

 

Chapter 8. Hardware Problem Determination 165