IBM 6.00E+04 manual PSeries 630 Model 6C4 and Model 6E4 Users Guide

Models: 6C4 6.00E+04

1 233
Download 233 pages 63.84 Kb
Page 196
Image 196

cd /usr/lpp/diagnostics/bin

./update_flash -f /tmp/fwupdate/RRyymmdd.img

Attention: Do not overlook the periods (.) in the commands shown above. AIX commands are case-sensitive. Type them exactly as shown.

You will be asked for confirmation to proceed with the firmware update and the required reboot. If you confirm, the system will apply the new firmware, reboot, and return to the AIX prompt. This may take up to ten minutes depending on the configuration of the system.

Attention: On some systems, the message Wait for rebooting before stopping may display on the system console. Do not turn off the system until the system has fully rebooted to the AIX login prompt. If a shutdown is necessary at that time, log in as root user and issue the shutdown command.

While the update is in progress, you will see Rebooting... on the display for several minutes.

The firmware update is complete.

178pSeries 630 Model 6C4 and Model 6E4 User's Guide

Page 196
Image 196
IBM 6.00E+04 manual PSeries 630 Model 6C4 and Model 6E4 Users Guide