MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE

(CONTINUED)

FIGURE F.24 – BRUSH BRACKET WRAP-AROUND COVER

BRUSH BRACKET

REMOVE (2) NUTS,

WASHERS, AND SCREWS

WRAP- AROUND COVER

27.Using the slot head screw driver, remove the two screws and nuts from the brush bracket wrap-around cover. Remove the cover. See Figure F.24.

FIGURE F.25 – MAIN GENERATOR BRUSH BRACKET CLAMPING BOLT

CLAMPING BOLT

BRUSHES (8)

BRUSH BRACKET

28. Lift the eight brushes from the main commu-

29. Using the 7/16” wrench, loosen (do not

tator. Note their positions for reassembly.

remove) the main generator brush bracket

 

clamping bolt. Note the position of the drill

 

spot for reassembly. See Figure F.25.