| OPERATION | ||||||||||
SAFETY PRECAUTIONS |
|
|
| DESIGN SUMMARY |
| |||||||
|
|
|
|
|
| WARNING |
|
|
| Control Panel |
| |
Do not attempt to use this equipment until y | ou |
| ||||||||||
have thoroughly read the engine manufacturerʼs | Both the engine and the welder controls are located on | |||||||||||
manual supplied with your welder. It includes | ||||||||||||
important safety precautions, detailed engine | one recessed panel at the exciter end of the machine. | |||||||||||
starting, operating and maintenance instructions, | The welder controls consist of a five step “Current | |||||||||||
and parts lists. |
|
|
|
| Range Selector” switch and a “Fine | Current | ||||||
Adjustment” rheostat. The welder is equipped with a | ||||||||||||
|
|
|
|
|
| ELECTRIC SHOCK can kill. |
|
|
| |||
|
|
|
|
|
| • Do not touch electrically live parts or | “Start” button, “Ignition” switch, “Idler” control switch, | |||||
|
|
|
|
|
| electrode with skin or wet clothing. | hour meter, a battery charging ammeter, an oil pres- | |||||
|
|
|
|
|
| • Insulate yourself from work and | sure gauge and engine coolant temperature gauge. | |||||
|
|
|
|
|
| ground |
|
|
|
| The control panel also contains a three prong ground- | |
|
|
|
|
|
| • Always wear dry insulating gloves. | ||||||
|
|
|
|
| ENGINE EXHAUST can kill. |
|
|
| ing type receptacle for auxiliary power. |
| ||
|
|
|
|
|
| • Use in open, well ventilated areas or | Welding Generator |
| ||||
|
|
|
|
|
| vent exhaust outside. |
|
|
|
| ||
|
|
|
|
| The Pipeliner® 200G uses the old style, round, all cop- | |||||||
|
|
|
|
| ||||||||
|
|
|
|
|
| MOVING PARTS can injure. |
|
|
| per FJW Generator frame which provides the customer | ||
|
|
|
|
|
| • Do not operate with doors open or | with the original “Classic” pipe welding arc. |
| ||||
|
|
|
|
|
| guards off. |
|
|
|
|
|
|
|
|
|
|
|
| • Stop engine before servicing. |
|
|
| Engine Idler |
| |
|
|
|
|
|
| • Keep away from moving parts. |
| |||||
The Pipeliner® 200G is equipped with an electronic | ||||||||||||
See additional warning information at | automatic engine idler. It automatically increases and | |||||||||||
| front of this operatorʼs manual. |
|
|
| decreases engine speed when starting and stopping | |||||||
welding or using auxiliary power. A | ||||||||||||
Operate the welder with the doors closed. Leaving | permits changing electrodes before the engine slows | |||||||||||
the doors open changes the designed air flow and | to its low idle speed. The “Idler” control switch on the | |||||||||||
can cause overheating. |
|
|
|
| panel locks the idler in the full speed position when | |||||||
desired. |
| |||||||||||
GENERAL DESCRIPTION |
|
|
| Auxiliary Power |
| |||||||
The Pipeliner® 200G is a heavy duty engine driven DC | 1.75 kw of nominal 120V DC. Output voltage is main- | |||||||||||
arc welding power source capable of providing DC | ||||||||||||
constant current output for stick welding and DC TIG | tained within ± 10% at all loads up to rated capacity. | |||||||||||
welding. With the addition of the optional | (See Optional Features for power plug kits). |
| ||||||||||
Feed Module the Pipeliner® 200G will provide con- | Welder Enclosure |
| ||||||||||
stant voltage output for running the |
| |||||||||||
The Pipeliner® 200G has a current range of | The complete welder is rubber mounted on a rugged | |||||||||||
DC amps with output ratings as follows: |
|
|
| steel “C” channel base. |
| |||||||
|
|
|
|
|
| RATED OUTPUT | DUTY CYCLE |
| The output terminals are placed at the side of the | |||
|
|
|
|
|
|
|
|
|
|
| machine so that they are protected by the door. The | |
|
|
|
|
|
| 200A @ 28V | 60% |
|
|
| ||
|
|
|
|
|
|
|
|
| output terminals are labeled (+) and |
| ||
|
|
|
|
|
| 200A @ 40V | 60% |
|
|
| Ignition System |
|
The units are also capable of providing 1.75 kw of |
| |||||||||||
A High Energy Distributor Type electronic ignition is | ||||||||||||
115V DC auxiliary power. |
|
|
|
| standard. |
| ||||||
This unit uses the GM 3.0L industrial water- cooled |
| |||||||||||
gasoline engine. |
|
|
|
|
|
|