F-11

 

TROUBLESHOOTING & REPAIR

F-11

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

Kubota - EUC - Codes

 

 

 

 

LIGHT CODE

 

FAILURE DETECTED

 

POSSIBLE CAUSE - CORRECTIVE MEASURE

 

 

 

 

 

 

 

 

 

 

LONG 1, SHORT 1

 

RPM IS OVER 115% OF RATED RPM (2070 RPM)

 

ACTUATOR IS STUCK - REMOVE ACTUATOR AND VERIFY

 

 

 

 

 

 

 

PLUNGER PULLS IN WHEN ENERGIZED

 

 

 

 

LONG 1, SHORT 2

 

LOW OIL PRESSURE DETECTED FOR 1 SECOND

 

LOW OIL - CHECK OIL LEVEL ON DIPSTICK

 

 

 

 

 

 

 

 

FAULTY OIL PRESSURE SWITCH - CHECK THAT "WK"

 

 

 

 

 

 

 

STUD IS OPEN WHEN ENGINE IS RUNNING

 

 

 

 

 

 

 

 

LEAD TO OIL PRESSURE SWITCH "WK" STUD MAY BE

 

 

 

 

 

GROUNDED - CHECK

 

 

 

 

LONG 1, SHORT 3

 

"L" TERMINAL IS GROUNDED ON ALTERNATOR

 

BROKEN OR LOOSE BELT

 

 

 

 

 

 

FOR 1 SECOND

 

LEAD TO "L" TERMINAL ON ALTERNATOR MAYBE

 

 

 

 

 

 

 

 

SHORTED TO GROUND- CHECK

 

 

 

 

 

 

 

 

FAULTY ALTERNATOR - CHECK

 

 

 

 

LONG 1, SHORT 4

 

HIGH WATER TEMPERATURE DETECTED

 

AMOUNT OR QUALITY OF COOLANT INCORRECT

 

 

 

 

 

 

FOR 1 SECOND

 

- CHECK

 

 

 

 

 

 

 

 

FAULTY WATER TEMPERATURE SWITCH - CHECK THAT

 

 

 

 

 

"WK" STUD IS OPEN WHEN ENGINE IS NOT RUNNING

 

 

 

 

 

LEAD TO WATER TEMPERATURE SWITCH MAY BE

 

 

 

 

LONG 1, SHORT 5

 

NOT ENABLED FOR LINCOLN PRODUCTS

 

GROUNDED - CHECK

 

 

 

 

 

 

 

 

 

 

 

LONG 2, SHORT 1

 

0 RPM IS DETECTED AND 12V IS DETECTED

 

FAULTY RPM SENSOR-CHECK FOR GOOD CONNECTION

 

 

 

FROM "L" TERMINAL ON ALTERNATOR

 

FAULTY ECU - CHECK FOR 12 VOLTS ON SUPPLY LEAD

 

 

 

 

 

TO RPM SENSOR FROM ECU

 

 

 

 

LONG 2, SHORT 2

 

CURRENT TO ACTUATOR IS OUT OF LIMIT

 

FAULTY ACTUATOR - CHECK FOR PROPER COIL

 

 

 

 

 

 

 

 

RESISTANCE

 

 

 

 

 

 

 

 

LEADS TO ACTUATOR MAY BE OPEN OR GROUNDED

 

 

 

LONG 2, SHORT 3

 

NOT ENABLED FOR LINCOLN PRODUCTS

 

- CHECK

 

 

 

 

 

 

 

 

 

 

 

LONG 2, SHORT 4

 

-50C WATER TEMPERATURE DETECTED

 

FAULTY WATER TEMPERATURE SENSOR - CHECK FOR

 

 

 

 

 

 

PROPER RESISTANCE

 

 

 

 

 

 

 

 

LEAD TO WATER TEMPERATURE SENSOR MAY BE OPEN

 

 

 

 

 

 

- CHECK FOR CONTINUITY

 

 

 

 

LONG 2, SHORT 5

 

150C WATER TEMPERATURE DETECTED

 

FAULTY WATER TEMPERATURE SENSOR - CHECK FOR

 

 

 

 

 

PROPER RESISTANCE

 

 

 

 

 

 

 

 

LEAD TO WATER TEMPERATURE SENSOR MAY BE

 

 

 

 

 

 

 

 

GROUNDED - CHECK

 

 

 

 

LONG 2, SHORT 6

 

0 VOLTS DETECTED FROM "L" TERMINAL ON

 

LEAD TO "L" TERMINAL ON ALTERNATOR MAY BE OPEN

 

 

 

 

ALTERNATOR FOR 1 SECOND

 

- CHECK FOR CONTINUITY

 

 

 

 

 

 

 

 

BROKEN OR LOOSE BELT - INSPECT

 

 

 

 

 

 

 

 

FAULTY ALTERNATOR - CHECK

 

 

 

 

LONG 2, SHORT 7

 

OVER 18 VOLTS DETECTED FROM ALTERNATOR

 

INCORRECT BATTERY - INSPECT

 

 

 

 

 

 

 

 

FAULTY ALTERNATOR - CHECK

 

 

 

 

LONG 2, SHORT 8

 

LESS THAN 4 VOLTS TO RPM SENSOR AND/OR

 

FAULTY ECU -CHECK FOR 12 VOLTS ON LEADS TO RPM

 

 

 

ACTUATOR SENSED BY ECU

 

SENSOR AND ACTUATOR FROM ECU

 

 

 

 

 

 

 

 

 

 

 

 

PIPELINER® 200