F-53 TROUBLESHOOTING & REPAIRF-53
MAIN GENERATOR FRAME REMOVAL AND REPLACEMENT PROCEDURE
(CONTINUED)
FIGURE F.19 – SELECTOR SWITCH LEAD REMOVAL
SELECTOR |
|
SWITCH |
|
TERMINAL |
|
LEAD (5) |
|
C | D |
A | B |
E |
|
9.Using the 1/2” wrench, remove the five heavy flex leads from the selector switch terminals. Label the leads for reassembly. See Figure F.19.
FIGURE F.20 – OUTPUT TERMINAL LEAD REMOVAL
|
| POSITIVE OUTPUT |
|
| TERMINAL AND LEAD |
C | D |
|
A | B |
|
E |
| 11. Using the 3/4” wrench, remove the heavy |
10. Using the 3/4” wrench, remove the copper | ||
strap from the negative output terminal. See | lead from the positive output terminal. See | |
Figure F.20. |
| Figure F. 20. |