| TROUBLESHOOTING & REPAIR | |||
| DC EXCITER ARMATURE & FIELD COILS |
| ||
| REMOVAL AND REPLACEMENT PROCEDURE |
| ||
Field Coils Removal Procedure | Reassembly: |
| ||
1. | Perform the DC Exciter Armature Removal | 7. Assemble the new coils to their respective | ||
2. | Procedure. |
| pole pieces. |
|
Using the 3/8” wrench, remove the leads from | 8. Assemble the coil and pole pieces to the | |||
| the brush holder. | Note lead placement for | exciter frame with four bolts. |
|
3. | reassembly. |
| 9. Make the necessary lead connections to the | |
Using the 1/2” wrench, remove the four bolts | idler board and 115VDC receptacle. | Wrap | ||
| (two on each side) holding the pole pieces to | the slices with tape. |
| |
4. | the exciter frame. | See Figure F.15. | 10. Assemble the armature and brushes. | |
Label and remove the tape and splices from | See the DC Exciter Armature Removal | |||
| the black and red leads that go to the idler | Procedure. |
| |
| board and 115VDC receptacle. See the |
|
| |
5. | Wiring Diagram. |
|
|
|
Carefully slide the coils and pole pieces from |
|
| ||
6. | the exciter frame. |
|
|
|
Remove the coils from the pole pieces. |
|
|