F-41 TROUBLESHOOTING & REPAIRF-41
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VDC SUPPLY) HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM
0 volts
50 volts | 2 ms |
This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 2 milliseconds in time.
Note: Scope probes connected at machine 115VDC receptacle.
SCOPE SETTINGS | |
Volts/Div | 50V/Div. |
Horizontal Sweep | 2 ms/Div. |
Coupling | DC |
Trigger | Internal |