F-63

TROUBLESHOOTING & REPAIR

F-63

Retest a machine:

 

 

RETEST AFTER REPAIR

 

 

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

 

machineʼs electrical characteristics.

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

• If you repair or replace any electrical components.

 

 

 

 

 

 

 

 

ENGINE OUTPUT

 

 

 

Engine

 

 

Mode

 

No Load RPM

 

 

Load RPM

 

 

 

 

 

 

 

 

 

Perkins

 

 

Low Idle

 

1375-1425

 

 

NA

 

 

Perkins

 

 

High Idle

 

1540-1650

 

 

1450-1600

 

 

Kubota

 

 

Low Idle

 

1390-1410

 

 

NA

 

 

Kubota

 

 

High Idle

 

1580-1600

 

 

1550-1600

 

 

GM (Gas)

 

 

Low Idle

 

1340-1360

 

 

NA

 

 

GM (Gas)

 

 

High Idle

 

1580-1600

 

 

1550-1600

 

 

 

 

WELDER DC OUTPUT

 

 

 

 

 

Current Control

 

Current Selector

 

Open Circuit

 

Load Volts

 

Load Amps

 

 

 

 

 

 

 

 

Rheostat

 

Switch

 

Voltage

 

 

 

 

 

 

Maximum

 

Maximum

 

88-98

 

33-39

 

300

 

 

DC AUXILIARY POWER RECEPTACLE OUTPUT

 

 

 

Open Circuit Voltage

 

Load Volts

 

 

Load Amps

 

 

 

 

 

124-138

 

115-130

 

 

 

 

15.0

 

 

 

 

FIELD AMPS AND VOLTS

 

 

 

 

(Current Rheostat at Maximum)

 

 

 

Exciter DC Volts

 

Main Shunt Field Amps

 

 

 

RPM

 

 

 

 

 

 

 

123 - 137

 

2.10-2.70

 

 

 

 

1540-1600

 