Lincoln Electric 200 service manual Welder DC Output, Rpm

Models: 200

1 145
Download 145 pages 41.63 Kb
Page 133
Image 133

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-63

TROUBLESHOOTING & REPAIR

F-63

Retest a machine:

 

 

RETEST AFTER REPAIR

 

 

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

 

machineʼs electrical characteristics.

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

• If you repair or replace any electrical components.

 

 

 

 

 

 

 

 

ENGINE OUTPUT

 

 

 

Engine

 

 

Mode

 

No Load RPM

 

 

Load RPM

 

 

 

 

 

 

 

 

 

Perkins

 

 

Low Idle

 

1375-1425

 

 

NA

 

 

Perkins

 

 

High Idle

 

1540-1650

 

 

1450-1600

 

 

Kubota

 

 

Low Idle

 

1390-1410

 

 

NA

 

 

Kubota

 

 

High Idle

 

1580-1600

 

 

1550-1600

 

 

GM (Gas)

 

 

Low Idle

 

1340-1360

 

 

NA

 

 

GM (Gas)

 

 

High Idle

 

1580-1600

 

 

1550-1600

 

 

 

 

WELDER DC OUTPUT

 

 

 

 

 

Current Control

 

Current Selector

 

Open Circuit

 

Load Volts

 

Load Amps

 

 

 

 

 

 

 

 

Rheostat

 

Switch

 

Voltage

 

 

 

 

 

 

Maximum

 

Maximum

 

88-98

 

33-39

 

300

 

 

DC AUXILIARY POWER RECEPTACLE OUTPUT

 

 

 

Open Circuit Voltage

 

Load Volts

 

 

Load Amps

 

 

 

 

 

124-138

 

115-130

 

 

 

 

15.0

 

 

 

 

FIELD AMPS AND VOLTS

 

 

 

 

(Current Rheostat at Maximum)

 

 

 

Exciter DC Volts

 

Main Shunt Field Amps

 

 

 

RPM

 

 

 

 

 

 

 

123 - 137

 

2.10-2.70

 

 

 

 

1540-1600

 

PIPELINER® 200

Page 133
Image 133
Lincoln Electric 200 service manual Welder DC Output, Rpm