F-7

TROUBLESHOOTING & REPAIR

F-7

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

 

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

1. Check the idler control switch

 

 

 

 

 

 

The engine will not return to low

1. Make sure the idler control

 

 

idle when the welding and

 

switch is set to the “Auto”

and associated leads for

 

 

 

auxiliary loads are removed.

position.

loose or faulty connections.

 

 

 

 

 

2. Make sure both welding and

See the Wiring Diagram.

 

 

 

 

 

2. Check the CURRENT

 

 

 

 

 

auxiliary loads are removed.

 

 

 

 

 

3. Check for mechanical

SENSING PC BOARD

 

 

 

 

 

Perform the Current Sense

 

 

 

 

restrictions in the idler and

Board Test. Replace if

 

 

 

 

 

throttle linkage (PERKINS

necessary.

 

 

 

 

 

code 10929 ONLY) There may

3. Perform the Idler Solenoid

 

 

 

 

 

be a problem with the ECU or

 

 

 

 

 

Throttle Body Controller or

Test. (PERKINS 10929

 

 

 

 

 

associated engine control

ONLY)

 

 

 

 

 

components on Kubota Diesel

4. Check for loose or faulty

 

 

 

 

 

(1114, 11316) and GM

connections at the idler PC

 

 

 

 

 

Gas(10660, 10913,

board (PERKINS) ECU in

 

 

 

 

 

11136)Contact the Lincoln

Kubota and Throttle Body

 

 

 

 

 

Electric Service Dept. 1-888-

Controller GM 3.0 liter.

 

 

 

 

 

935-3877.

5. The idler PC board

 

 

 

 

 

 

(PERKINS) ECU in Kubota or

 

 

 

 

 

Throttle Body Controller -GM

 

 

 

 

 

3.0 liter may be faulty.

 

 

 

 

 

 

Contact the Lincoln Electric

 

 

 

 

 

 

Service Dept. 1-888-935-

 

 

 

 

 

 

3877.

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.