F-43 TROUBLESHOOTING & REPAIRF-43
TYPICAL DC WELD VOLTAGE WAVEFORM
MACHINE LOADED – SELECTOR SWITCH AT MAXIMUM
0 volts
20 volts | 5 ms |
MACHINE LOADED TO 200 AMPS AT 40VDC
This is the typical DC welding output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank.
Note: Scope probes connected at machine output terminals.
SCOPE SETTINGS | |
Volts/Div | 20V/Div. |
Horizontal Sweep | 5 ms/Div. |
Coupling | DC |
Trigger | Internal |