| TROUBLESHOOTING & REPAIR |
| |||||
|
|
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED |
| |
| (SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION |
| |
| The actual welding current is | OUTPUT PROBLEMS |
| 1. The engine RPM may be low. |
| ||
|
|
| |||||
| 1. Check the welding cables for |
|
| ||||
| much less than is indicated on | loose or faulty connections. |
| If necessary perform the |
| ||
| the dials. |
| 2. The welding cables may be |
| Engine Throttle Adjustment |
| |
|
|
| Test. (PERKINS code 10929 |
| |||
|
|
| excessively long or coiled. |
| ONLY) | DC Exciter Test. |
|
|
|
| 3. Check the main DC generator |
| 2. Perform the |
| |
|
|
| brushes for good commutation |
| 3. Check the fine current control |
| |
|
|
| and alignment. Contact the |
|
| ||
|
|
| Lincoln Electric Service Dept. 1- |
| field rheostat for resistance |
| |
|
|
|
| and proper operation. Normal |
| ||
|
|
|
| resistance is 64 ohms. Check |
| ||
|
|
|
|
| associated wires for loose or |
| |
|
|
|
|
| faulty connections. See the |
| |
|
|
|
|
| Wiring Diagram. |
| |
|
|
|
|
| 4. Check the current range |
| |
|
|
|
|
| selector switch and contacts |
| |
|
|
|
|
| for proper operation. |
| |
|
|
|
|
| 5. Perform the | Main Generator |
|
|
|
|
|
| Shunt Field Winding Test. |
| |
|
|
|
|
| 6. The main armature may be |
| |
|
|
|
|
| faulty. Check for grounds. |
| |
| The actual welding current is | 1. Check the main DC generator |
| 1. The engine operating speed |
| ||
| much greater than is indicated | brushes for good commutation |
| may be too high. If necessary |
| ||
| on the dials. |
| and alignment. Contact the |
| perform the | Engine Throttle |
|
|
|
| Lincoln Electric Service Dept. |
| Adjustment Test. (PERKINS |
| |
|
|
|
| code 10929 ONLY) |
| ||
|
|
|
|
| 2. While the machine is loaded, |
| |
|
|
|
|
| check the series coils for signs |
| |
|
|
|
|
| of “arcing.” This condition |
| |
|
|
|
|
| could point to shorted turns in |
| |
|
|
|
|
| the series coils. |
| |
|
|
|
|
| 3. Perform the | DC Exciter Test. |
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call