F-6

TROUBLESHOOTING & REPAIR

F-6

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

The actual welding current is

OUTPUT PROBLEMS

 

1. The engine RPM may be low.

 

 

 

 

 

1. Check the welding cables for

 

 

 

much less than is indicated on

loose or faulty connections.

 

If necessary perform the

 

 

the dials.

 

2. The welding cables may be

 

Engine Throttle Adjustment

 

 

 

 

Test. (PERKINS code 10929

 

 

 

 

excessively long or coiled.

 

ONLY)

DC Exciter Test.

 

 

 

 

3. Check the main DC generator

 

2. Perform the

 

 

 

 

brushes for good commutation

 

3. Check the fine current control

 

 

 

 

and alignment. Contact the

 

 

 

 

 

Lincoln Electric Service Dept. 1-

 

field rheostat for resistance

 

 

 

 

 

and proper operation. Normal

 

 

 

 

888-935-3877.

 

resistance is 64 ohms. Check

 

 

 

 

 

 

associated wires for loose or

 

 

 

 

 

 

faulty connections. See the

 

 

 

 

 

 

Wiring Diagram.

 

 

 

 

 

 

4. Check the current range

 

 

 

 

 

 

selector switch and contacts

 

 

 

 

 

 

for proper operation.

 

 

 

 

 

 

5. Perform the

Main Generator

 

 

 

 

 

 

Shunt Field Winding Test.

 

 

 

 

 

 

6. The main armature may be

 

 

 

 

 

 

faulty. Check for grounds.

 

 

The actual welding current is

1. Check the main DC generator

 

1. The engine operating speed

 

 

much greater than is indicated

brushes for good commutation

 

may be too high. If necessary

 

 

on the dials.

 

and alignment. Contact the

 

perform the

Engine Throttle

 

 

 

 

Lincoln Electric Service Dept.

 

Adjustment Test. (PERKINS

 

 

 

 

1-888-935-3877.

 

code 10929 ONLY)

 

 

 

 

 

 

2. While the machine is loaded,

 

 

 

 

 

 

check the series coils for signs

 

 

 

 

 

 

of “arcing.” This condition

 

 

 

 

 

 

could point to shorted turns in

 

 

 

 

 

 

the series coils.

 

 

 

 

 

 

3. Perform the

DC Exciter Test.

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

PIPELINER® 200

Page 76