F-5

TROUBLESHOOTING & REPAIR

F-5

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

OUTPUT PROBLEMS

1. Check the fine current control

 

 

 

 

The welding output varies

 

1. Check for loose or faulty

 

abnormally. The auxiliary output

welding cables.

field rheostat for resistance

 

 

remains constant. The engine is

2. This may be a normal

and proper operation. Normal

 

resistance is 64 ohms. Check

 

operating correctly.

 

condition. The machine will

associated wires for loose or

 

 

 

normally lose some output as

faulty connections. See the

 

 

 

 

the components are heated.

Wiring Diagram.

 

 

 

 

3. Check for loose, worn, dirty or

2. Perform the Main Generator

 

 

 

poorly seated main DC

Shunt Field Winding Test.

 

 

 

 

generator brushes.

3. Check the current range

 

 

 

 

4. The main armature

 

 

 

 

selector switch and contacts

 

 

 

 

commutator may need

for proper operation.

 

 

 

 

cleaning.

4. While the machine is loaded,

 

 

 

 

check the interpole and series

 

 

 

 

coils for signs of “arcing.”

 

 

 

 

 

This condition would indicate

 

 

 

 

shorted turns in the “arcing”

 

 

 

 

 

coil.

 

 

 

 

 

5. The main armature may be

 

 

 

 

 

faulty. Check for grounds.

 

 

The engine starts and runs at

1. Check the DC receptacle and

1. Check for loose or faulty

 

 

the correct speed, but there is

plug for loose or faulty

connections or wires at the

 

 

no DC auxiliary output voltage

connections.

120 VDC receptacle and

 

 

at the 115VDC receptacle. The

2. Check the 15 Amp fuse. (Not

associated circuitry. See the

 

 

welding generator is functioning

Wiring Diagram.

 

 

correctly.

 

on GM 3.0L gas)

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.