BB-3

OPERATION

 

BB-3

Cranking System

 

COLD WEATHER STARTING

 

A 12V electric starter is standard.

 

With a fully charged battery and a proper weight oil, the

Air Cleaner

 

engine should start satisfactorily even down to about -

 

15°F -(26°C). If the engine must be frequently started

Heavy duty two-stage dry type

 

at or below -15°F -(26°C), it may be desirable to install

Exhaust

 

cold-starting aides.

 

 

 

Note: Extreme cold weather starting may require

A muffler and stainless steel exhaust outlet pipe are

longer glow plug operation

 

 

standard.

 

 

 

WARNING

 

Engine Hour Meter

 

 

 

 

 

Under NO conditions should ether or other starting

A meter to record the hours of operation.

 

ENGINE OPERATION

 

fluids be used!

 

 

 

------------------------------------------------------------------------

Operate the welder with the doors closed. Leaving the

STOPPING the ENGINE

 

 

doors open changes the designed air flow and can

1. Turn the “IGNITION” switch to “OFF”

 

cause overheating.

 

At the end of each dayʼs welding, check the crankcase

STARTING THE PIPELINER® 200D PERKINS

oil level, drain accumulated dirt and water from the

sediment bowl under the fuel tank and refill the fuel

104.22 DIESEL ENGINE

 

tank to minimize moisture condensation in the tank.

1. Turn the “IDLER” switch to “HIGH”.

 

Also, running out of fuel tends to draw dirt into the fuel

 

system.

 

 

2. Turn the “IGNITION” switch to “ON”.

 

When hauling the welder between job sites, close the

3. Press the Glow Plug button for 20 to 30 seconds.

fuel feed valve beneath the fuel tank.

 

(maximum 60 seconds).

 

If the fuel supply is cut off or runs out while the fuel

4. Press the Start button. When the engine starts run-

pump is operating, air may be entrapped in the fuel dis-

tribution system. If this happens, bleeding of the fuel

ning, release both buttons. If the engine fails to start

system may be necessary. Use qualified personnel to

in 20 seconds, wait 30 seconds and repeat the

do this per the instructions in the MAINTENANCE sec-

above procedure.

 

tion of this manual.

 

 

5. Observe the oil pressure. If no pressure shows with-

 

PIPELINER® 200D WITH PERKINS 104.22

 

in 30 seconds, stop the engine and consult the

 

 

engine operating manual. To stop the engine, turn

 

DIESEL ENGINE

 

 

the “IGNITION” switch to “OFF”.

 

 

 

TYPICAL FUEL CONSUMPTION DATA

 

6. If the engine protection warning light comes on dur-

 

Low idle (1400 RPM )

 

.33gal/hr (1.25ltrs/hr )

 

No Load

 

 

 

ing cranking or after start up, the “IGNITION” switch

 

High idle ( 1800 Rpm )

 

.39gal/hr (1.48ltrs/hr )

must be turned “OFF” to reset the engine protection

 

No load

 

 

 

system.

 

 

200 Amps @ 28 Volts

 

.67gal/hr (2.54ltrs/hr )

 

 

200 Amps @ 40 Volts

 

.75gal/hr (2.84ltrs/hr )

7. Allow the engine to run at high idle speed for sever-

 

Auxiliary Power

 

.50gal/hr (1.89ltrs/hr)

al minutes to warm the engine. Stop the engine and

 

15 Amps @ 120 Volts

 

recheck the oil level after allowing sufficient time for

 

 

 

 

 

 

 

 

 

 

 

 

the oil drain into the pan. If the level is down, fill it to

 

 

 

 

 

 

the full mark again. The engine controls were prop-

 

 

 

 

 

 

erly set at the factory and should require no adjust-

 

 

 

 

 

 

ing when received.

 

 

 

 

 

 

 

PIPELINER® 200D PERKINS

Page 33
Image 33
Lincoln Electric service manual Cold Weather Starting, Diesel Engine, Starting the Pipeliner 200D Perkins