Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-19TROUBLESHOOTING & REPAIRF-19

MAIN GENERATOR SHUNT FIELD WINDING TEST

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This test will help determine whether or not the main shunt field coils are shorted, open, or grounded.

MATERIALS NEEDED

Volt/ohmmeter (Multimeter)

Wiring Diagram

PIPELINER® 200

Page 89
Image 89
Lincoln Electric 200 service manual 19TROUBLESHOOTING & REPAIRF-19, Main Generator Shunt Field Winding Test