MAIN GENERATOR SHUNT FIELD WINDING TEST (continued)

FIGURE F.6 – PLUG P10 PIN ASSIGNMENTS

PIN 3

PIN 5

TAB

Return to Section TOC

Return to Master TOC

5.Locate the blue (U) (pin 3) and the brown (N) (pin 5) leads in the harness plug. See Figure F.6.

6.Using the volt/ohmmeter, measure the resis- tance between the blue and the brown lead. Normal resistance is approximately 40 ohms.

7.Also measure the resistance from either lead (blue or brown) to ground. This resis- tance should be at least 500,000 ohms.

8.If the test does not meet the resistance specifications, then check the harness plug for loose connections or shorted leads.

9.If the plug and associated leads are okay, the shunt field coils may be faulty. Replace the shunt field coils.

10.If the test does meet the resistance specifi- cations, the main shunt coils are okay.

11.Replace plug P10, making sure the leads and plug are secure.

12.After the test and repairs are completed, close and latch the right side door.