Ricoh AP305 Remove the green cap from the new oil bottle, Close the fuser oil bottle cover

Models: AP305

1 156
Download 156 pages 32.85 Kb
Page 121
Image 121

Replacing Consumables

RCAUTION:

When accessing the inside of the machine, do not touch any sec- tions other than those specified in this manual. If you do, it might result in receiving a burn or inju- ry.

Important

There are three ozone filters in this printer. Two of them are set inside in the front, one of them is set in the rear. Be careful when replacing the ozone filters as the front side filter is a different shape from the rear side filter.

Disposal can take place at our au- thorized dealer or at appropriate collection sites.

Dispose of used ozone filters as general burnable refuse.

A Turn off the printer's power switch.

B Replace the oil bottle.

B Open the fuser oil bottle cover of the printer.

TFWX090E

C Remove the used oil bottle from the printer carefully.

D Insert the new oil bottle into the oil bottle case.

6

TFWX100E

A Remove the green cap from the new oil bottle.

Important

Hold the clear cap while turning the green cap. Do not remove the clear cap.

TFWX031E

E Close the fuser oil bottle cover.

Important

The fuser oil bottle cover should be kept closed.

C Replace the ozone filter on the back side of the printer.

A Remove

the

ventilator

hole

cover.

 

 

 

 

 

 

TFWX060E

91