3INSTALLATION AND CONNECTIONS
Connecting SENSOR ALARM OUT terminals
The SENSOR ALARM OUT terminals are used to relay alarm signals whenever one of the digital video recorder’s motion sensors is triggered. Normally in an open condition, a terminal adopts low condition when a sensor for the corresponding camera number has been triggered.
1K |
| Rating for each terminal |
|
| z Maximum current: 25 mA |
|
| z Maximum voltage: 25 V |
|
| |
|
|
Connecting CONTROL terminals
The connections for a remote control circuit are shown below. This digital video recorder can be remotely controlled when a
C R1 R2
R1 | R2 |
Connecting the power cord
1 When you have finished making all the other connections, make sure the voltage is 120
There is no power switch. The display indicators flash, and after a few moments, the monitor screen displays the camera image.
120 V-240 V AC (50/60 Hz)
zWhen turning the power on for the first time “PLEASE SET THE CLOCK” is displayed on the monitor screen. Follow the procedures on P.17 to set the clock.
zIf the clock is already set
The operation display area is displayed.
Operation |
|
display area |
|
|
02
INTRODUCTION
(When operated (When combined independently) with R2 Shift key)
SW 1 : Camera 1*: INDEX +
SW 2 : Camera 2*: INDEX -
SW 3 : Camera 3*: AUTO FOCUS
SW 4 : Camera 4*: SEQUENCE
SW 5 : Camera 5*: MON2 SW 6 : Camera 6*: PLUS
SW 7 : Camera 7*: QUAD
SW 8 : Camera 8*: MULTI
SW 9 : Camera 9*: MENU RESET
SW 10 : Camera 10:
SW 11 : Camera 11: PAN left
SW 12 : Camera 12: PAN right
SW 13 : Camera 13: TILT down
SW 14 : Camera 14: TILT up
SW 15 : Camera 15: ZOOM wide SW 16 : Camera 16: ZOOM tele
SW 17 : REC/STOP SW 18 : PLAY/STOP
SW 19 : STILL
SW 20 : SEARCH
SW 21 : SHIFT (Doubles with R1)
SW 22 : PLAY
SW 23 : REC
SW 24 : MENU
SW 25 : EXIT/OSD
SW 26 : +
SW 27 : -
SW 28 : →
SW 29 : ←
SW 30 : ZOOM
SW 31 : COPY
SW 32 : TIMER
zIf the POWER indicator starts flashing;
If a problem occurs during use, the POWER indicator will begin to flash and an explanation will be displayed. In these cases, contact a Sanyo service center.
POWER | Meaning | |
indicator status | ||
| ||
|
| |
| There is a problem with the hard disk. The | |
Four flashes per | hard disk must be replaced or initialized. | |
second | Contact a Sanyo service center to recover | |
| recorded images. | |
|
| |
One flash per | There is a problem with the fan. | |
second | ||
| ||
|
|
z The power cord’s ground terminal is not provided for |
enhanced safety; rather, it can be used to reduce the |
level of interference when the digital video recorder is |
connected to analog devices. |
If a large amount of noise is generated when the digital |
zUse a resistance of 1/10 ohms or more and with a D ranking (Precision within ±0.5%).
zThe remote control cable should be no more than 5 m long.
* The
video recorder is connected to analog devices, connect |
this terminal to the building’s earth. |
14 | English |