3RECORD SET
2 Turn the jog dial to select setting (OFF, for example), and then turn the shuttle dial clockwise.
“REMAINING DISK WARNING” changes to “1%” from “**”.
[Settings] ( indicates default setting)
Setting | Description |
OFF | Recording is stopped when the normal recording area |
| becomes full. |
Overwriting automatically starts from the beginning of ON the normal recording area when it becomes full.
.
|
| <RECORDING CONDITIONS SET> | |
|
| NORMAL RECORDING AREA |
|
|
| OVERWRITE | : OFF |
|
| ALARM RECORDING AREA |
|
|
| OVERWRITE | : ON |
Remaining disk |
| REMAINING DISK WARNING | : 1 % |
| |||
warning |
| SERIES REC | : OFF |
|
| AUTO DELETE | : OFF |
zIf this is set to “OFF”, the FULL indicator or ALARM FULL indicator will start to flash when the remaining
“REMAINING DISK WARNING”.
3 Use the same procedure to set “ALARM RECORDING AREA” to “OFF”.
4 Turn the jog dial to select “REMAINING DISK WARNING”, and then turn the shuttle dial clockwise.
5 Turn the jog dial to set the remaining capacity, and then turn the shuttle dial clockwise.
The remaining capacity can be set anywhere between 1% (default) and 10%.
<RECORDING CONDITIONS SET> NORMAL RECORDING AREA
OVERWRITE : OFF ALARM RECORDING AREA
OVERWRITE : OFF
REMAINING DISK WARNING | : 1 % |
SERIES REC | : OFF |
AUTO DELETE | : OFF |
6 Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to the normal screen.
EXIT/OSD
Turn “OVERWRITE” to “OFF” to display the remaining memory for the current recording area on the operating display.
Also, if remaining memory reaches the set percentage, the FULL indictor flashes for normal recording area and the ALARM FULL indicator flashes for the alarm recording area. When the remaining memory runs out, the indicator switches to a permanently lit condition and recording stops automatically.
|
| |||
FULL indicator | ALARM FULL indicator | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation |
| Remaining | ||
display area |
|
| capacity | |
|
|
|
| display |
|
|
| ||
|
|
|
|
|
| EN A ALARM 0000 | |||
02 |
|
|
When the normal recording area or the alarm recording area become full
Make a new “AREA FULL RESET” setting for “NORMAL RECORDING AREA” and “ALARM RECORDING AREA” on the <RECORDING AREA SET> screen. (JP.66)
| <RECORDING AREA SET> |
|
|
| ||
TOTAL CAPACITY |
|
| : | 82GB | ||
NORMAL RECORDING AREA | : | 80 | % | |||
| AREA FULL RESET |
|
|
|
| |
ALARM RECORDING AREA |
|
| : | 19 | % | |
| AREA FULL RESET |
|
|
|
| |
ARCHIVE AREA |
|
| : | 1 | % | |
| AREA FULL RESET |
|
|
|
|
CAUTION : WHEN THE AREA SETTING IS CHANGED,
THE WHOLE AREA WILL BE INITIALIZED !
SETTINGS