3RECORD SET
6 Turn the jog dial to select a recording rate (7.5, for example), and then turn the shuttle dial clockwise.
Camera No. 1 is now set to record at a rate of 7.5. The cursor moves to “02”.
Valid recording rates
30*, 15, 7.5, 3.75, 1.875, 1, 0.5, 0.33, 0.25, 0.2, 0.1, 0.05, 0.03, OFF (Unit: FPS)
*A selection cannot be made when
7 Set recording rates for Camera No. 2 and Camera No. 3 in the same way.
8 With the cursor flashing on “04” (camera number), turn the jog dial to select “OFF”, and then turn the shuttle dial clockwise.
Video from Camera No. 4 will not be recorded.
9 Use the same procedure to set Camera No. 5 through Camera No. 16 to “OFF”.
| <PROGRAM | REC SET> |
| |
| PROGRAM | : |
| |
SELECT INDIVIDUAL | CAMERA RATE(FPS) | |||
01: 7.5 | 02: 1 | 03: | 1 | 04: OFF |
05: OFF | 06: OFF | 07: | OFF | 08: OFF |
09: OFF | 10: OFF | 11: | OFF | 12: OFF |
13: OFF | 14: OFF | 15: | OFF | 16: OFF |
| NORMAL REC : | 55H |
|
10 If necessary, use this procedure to setup other programs (i.e., No. 2 through No. 4).
11 Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to the normal screen.
EXIT/OSD
Timer settings
Use the following procedures to set recording start and stop times using the timer function.
Timer setting items
Timer setting items allow you to set times at which to start and stop recording or recording rate on each specified day of the week.
|
| (1) | (2) | (3) | (4) | (5) | (6) | ||||||||
|
|
|
|
|
|
|
| <TIMER | SET> |
|
|
|
|
| |
|
|
| WEEK | START | STOP | PROGRAM | FPS | SET | |||||||
|
|
| SUN | OFF | 15 | FPS | OFF | ||||||||
|
|
| MON | OFF | 15 | FPS | OFF | ||||||||
|
|
| TUE | OFF | 15 | FPS | OFF | ||||||||
|
|
| WED | OFF | 15 | FPS | OFF | ||||||||
|
|
| THU | OFF | 15 | FPS | OFF | ||||||||
|
|
| FRI | OFF | 15 | FPS | OFF | ||||||||
(7) |
|
| SAT | OFF | 15 | FPS | OFF | ||||||||
|
|
| DLY | OFF | 15 | FPS | OFF | ||||||||
|
|
| EXT | ***** | ***** | OFF | 15 | FPS | OFF |
(1) WEEK
These fields are used to select the days of the week for timer settings. When a day in the “WEEK” column is flashing, it can be set to another day.The 7th line (default: “SAT”) and 8th line (default: “DLY”) are used for timer recording settings of over 24 hours.
(2) START
These fields are used to enter the time
(3) STOP
These fields are used to enter the time
If the stop and end times are on different days (i.e., midnight is included), a “T” will be displayed to the left of the end time.
(4) PROGRAM
These fields are used to enable timer recording using the program function
(5) FPS
These fields are used to set the recording rate. No setting is necessary here when using program recording.
(6) SET
When set to “ON”, timer is enabled.
When set to “OFF”, timer is disabled.
(7) Settings for timer recording of over 24 hours
Use these lines for timer recording spanning more than 24 hours.
SETTINGS
74 | English |