4GENERAL SET
2 Turn the jog dial to select “1. DISPLAY SET”, and then turn the shuttle dial clockwise.
The <DISPLAY SET> screen is displayed.
(1) |
| <DISPLAY SET> |
|
| ||
| DATE | : ON |
|
|
| |
(2) |
|
|
|
|
|
|
| TIME | : ON |
|
| ||
(3) |
| QUALITY | : ON |
|
| |
(4) |
| AUDIO | : ON |
|
| |
(5) |
| ALARM COUNT | : ON |
|
| |
(6) |
| ALARM TYPE | : ON |
|
| |
(7) |
| TITLE | : ON |
|
| |
|
| VIDEO LOSS | : ON |
|
| |
(1) | (2) |
| (3)(4) | (6) | (5) | |
EN A ALARM 0000 | ||||||
| 02 |
|
|
|
| |
| (7) |
|
|
|
|
3 Turn the shuttle dial clockwise.
“ON” for the (1) “DATE” flashes. This can be set to “OFF” turning the jog dial to remove the date from the operation display area.
4 Turn the shuttle dial clockwise.
The cursor moves to the time entry.
The following settings are carried out with the shuttle dial and jog dial.
zVertical cursor movement: Turn the jog dial.
zCursor movement to the right: Turn the shuttle dial clockwise.
zModification of values: Turn the shuttle dial clockwise, and then with the setting value flashing, turn the jog dial.
zConfirmation of values: Turn the shuttle dial clockwise.
5 Perform the following if so required.
zTIME (OFF):
Time is not displayed during recording or playback.
zQUALITY (OFF):
Picture quality mode is not displayed during recording or playback.
zAUDIO (OFF):
Audio recording settings are not displayed during recording or playback.
zALARM COUNT (OFF):
The current number of alarms is not displayed.
zALARM TYPE (OFF):
The type of alarm recording is not displayed.
zTITLE (OFF):
Camera titles are not displayed.
The content of the operation display area changes when the setting for “ALARM RECORDING” (JP.77) from <ALARM REC MODE SET> is switched.
When turned “OFF”:
The alarm count and type are not displayed. When turned “ENABLED”:
The operation display area changes as follows.
z“ALARM” is displayed when alarm video is recorded or played back.
z“PRE” is displayed when
z“ARCHIV” is displayed for playback from the archive area.
6 Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to the normal screen.
EXIT/OSD
zA maximum of 9,999 alarms can be displayed in the operation display area. When this number is exceeded, the count returns to 0000.
\
Setting display for video loss
Use the following procedure to display “VIDEO LOSS!” when the camera video is interrupted.
1 Turn the jog dial to select “VIDEO LOSS”, and then turn the shuttle dial clockwise.
<DISPLAY SET>
DATE | : ON |
TIME | : ON |
QUALITY | : ON |
AUDIO | : ON |
ALARM COUNT | : ON |
ALARM TYPE | : ON |
TITLE | : ON |
|
|
VIDEO LOSS | : ON |
2 Turn the jog dial to display “ON”, and then turn the shuttle dial clockwise.
3 Press the [EXIT/OSD] button.
The setting procedure is ended and the display returns to the normal screen.
EXIT/OSD
English | 87 |