GP_ATV58_EN.fm Page 69 Mardi, 2. avril 2002 6:09 18

Macro-Configurations

This parameter can always be displayed but can only be modified in programming mode (access switch in position ) and in stop mode with the speed controller locked.

It can be used to automatically configure an application-specific function. Three application-specific functions are available.

-Handling (Hdg)

-Variable torque for pump and fan applications (VT)

-General use (GEn)

A macro-configuration automatically assigns the I/O and parameters, activating the functions required for the application. The parameters related to the programmed functions are available.

Factory setting : Handling

Speed controller :

I/O assignment according to the macro-configuration

 

Hdg : Handling

GEn : Gen Use.

VT : Var. Torque

 

 

 

 

Logic input LI1

forward

forward

forward

 

 

 

 

Logic input LI2

reverse

reverse

reverse

 

 

 

 

Logic input LI3

2 preset speeds

jog operation

reference switching

 

 

 

 

Logic input LI4

4 preset speeds

freewheel stop (1)

injection braking

 

 

 

 

Analog input AI1

summing ref.

summing ref.

speed ref. 1

 

 

 

 

Analog input AI2

summing ref.

summing ref.

speed ref. 2

 

 

 

 

Relay R1

controller fault

controller fault

controller fault

 

 

 

 

Relay R2

downstr. contactor ctrl

mot. therm. state

freq. setpoint reached

 

 

reached

 

 

 

 

 

Analog output AO1

motor frequency

motor frequency

motor frequency

 

 

 

 

Extension cards :

 

 

 

 

 

 

 

I/O assignment according to the macro-configuration

 

 

 

 

 

 

Hdg : Handling

GEn : Gen Use.

VT : Var. Torque

 

 

 

 

Logic input LI5

8 preset speeds

clear fault

freewheel stop (1)

 

 

 

 

Logic input LI6

clear fault

limit torque

ramp switching

 

 

 

 

Analog input AI3

summing ref.

summing ref.

NO

or

 

 

 

speed feedback

speed feedback

speed feedback

Inputs A, A+, B, B+

 

 

 

 

 

 

 

Logic output LO

current thresh reached

downstr. contactor ctrl

high speed reached

 

 

 

 

Analog output AO

Motor current

Motor current

Motor current

 

 

 

 

(1) In order to start, the logic input must be linked to the + 24 V (function active at 0).

CAUTION : Ensure that the programmed macro-configuration is compatible with the wiring diagram used. This check is particularly important on the ready-assembled ATV58E if the factory configuration is modified; the diagram may also require modification.

69

ENGLISH

Page 215
Image 215
Schneider Electric altivar 58 telemecanique, vw3-a58101 manual Macro-Configurations, Factory setting Handling