Schneider Electric vw3-a58101 Encoder input application functions, Preset setpoints, Reference

Models: vw3-a58101 altivar 58 telemecanique

1 294
Download 294 pages 38.42 Kb
Page 244
Image 244

GP_ATV58_EN.fm Page 98 Mardi, 2. avril 2002 6:09 18

Configurable I/O Application Functions

ENGLISH

Analog input application functions

Preset setpoints:

2 or 4 preset setpoints require the use of 1 or 2 logic inputs respectively:

 

2 preset setpoints

 

 

 

4 preset setpoints

 

 

 

 

 

 

Assign: LIx to Pr2

 

 

Assign: LIx to Pr2 then, LIy to Pr4

 

 

 

 

 

 

LIx

Reference

LIy

LIx

 

Reference

 

 

 

 

 

 

0

Analog reference

0

0

 

Analog reference

 

 

 

 

 

 

1

Process max (= 10 V)

0

1

 

PI2 (adjustable)

 

 

 

 

 

 

 

 

1

0

 

PI3 (adjustable)

 

 

 

 

 

 

 

 

1

1

 

Process max (= 10 V)

 

 

 

 

 

 

Torque limit : (Only with an I/O extension card with analog input AI3)

The signal applied at AI3 operates in a linear fashion on the internal torque limit (parameter TLI in the "drive menu") :

-If AI3 = 0V : limit = TLI x 0 = 0

-If AI3 = 10 V : limit = TLI.

Applications : Torque or traction correction, etc.

Encoder input application functions :

(Only with an I/O extension card with encoder input)

Speed regulation : Is used for speed correction using an incremental encoder or sensor. (See documentation supplied with the card).

Summing speed reference : The setpoint from the encoder input is summed with AI1. (See documentation supplied with the card)

Applications :

-Synchronization of the speed of a number of speed controllers. Parameter PLS in the "drive" menu is used to adjust the speed ratio of one motor in relation to that of another.

-Setpoint via encoder.

98

Page 244
Image 244
Schneider Electric vw3-a58101, altivar 58 telemecanique Encoder input application functions, Preset setpoints, Reference