GP_ATV58_EN.fm Page 79 Mardi, 2. avril 2002 6:09 18

Adjust Menu

Code

Description

Adjustment range

Factory setting

 

 

 

 

FFt

TripThreshNST-Hz

0 to HSP

0 Hz

 

 

 

 

Freewheel stop trip threshold: When a stop on ramp or fast stop is requested, the type of stop selected is activated until the speed falls below this threshold. Below this threshold, freewheel stop is activated. This parameter can only be accessed if the R2 relay is not assigned to the “BLC: Brake Logic” function, and if an “on ramp” or “fast” type stop has been selected in the drive menu.

bIP Brake impul.

No - Yes

No

 

 

 

 

Brake release pulse

Yes : While the brake is released the torque is always in the FW (foward) control corresponds to the direction, regardless of the direction requested.

Check that the motor torque direction for FW (foward) control corresponds to the direction of increase in load; if necessary reverse 2 motor phases.

no : while the brake is released the torque is in the requested direction of rotation.

dtS

Tacho Coeff.

1 to 2

1

 

 

 

 

Multiplication coefficient of the feedback associated with tachogenerator function :

 

dtS =

 

9

 

 

 

 

tacho voltage at HSP HSP

 

 

 

 

 

 

 

 

 

 

 

rPG

PI Prop.Gain

 

0.01 to 100

1

 

 

 

 

 

 

 

Proportional gain of the PI regulator

 

 

 

 

 

 

 

 

rIG

PI Int.Gain

 

0.01 to 100/s

1 / s

 

 

 

 

 

 

 

Integral gain of the PI regulator

 

 

 

 

 

 

 

 

 

 

FbS

PI Coeff.

 

1 to 100

1

 

 

 

 

 

 

 

PI feedback multiplication coefficient

 

 

 

 

 

 

 

 

PIC

PI Inversion

 

No - Yes

No

 

 

 

 

 

 

 

Reversal of the direction of correction of the PI regulator

 

 

no : normal yes : reverse

 

 

 

 

 

 

 

 

 

Ftd

Freq.Lev.Att- Hz

LSP to HSP

50/60 Hz

 

 

 

 

 

 

 

Motor frequency threshold above which the logic output changes to 1

 

 

 

 

 

 

F2d

Freq.Lev.2 - Hz

LSP to HSP

50/60 Hz

 

 

 

 

 

 

 

Same function as Ftd, for a second frequency value

 

 

 

 

 

 

 

 

Ctd

Curr.Lev.Att-

A

0 to 1.36 In (1)

1.36 In (1)

 

 

 

 

 

 

 

Current threshold above which the logic output or the relay changes to 1

 

 

 

 

 

 

 

ttd

ThermLev.Att-

%

0 to 118%

100%

 

 

 

 

 

 

 

Motor thermal state threshold above which the logic output or the relay changes to 1

 

 

 

 

 

 

 

tL2

Trq.Limit 2

- %

0 to 200% (2)

200%

 

 

 

 

 

 

 

Second torque limit level activated by a logic input

 

(1)In corresponds to the speed controller nominal current indicated in the catalog and on the speed controller identification label for "high torque" applications.

(2)100% corresponds to the nominal torque of a motor with a power rating equal to that associated with the speed controller for "high torque" applications.

Parameters in gray boxes appear if an I/O extension card is installed

79

ENGLISH

Page 225
Image 225
Schneider Electric altivar 58 telemecanique, vw3-a58101 manual To HSP, to Proportional gain of the PI regulator, 01 to 100/s