33
GB
1.
1.
2.
3.
4.
5.
6.
Messages
1. Batteries in the operator unit
(LOW BAT-T) or the base
(LOW BAT-B) low.
2. Overload: From 150kg.
3. Implausible analysis result
– check individual pro-
gramming.
4. + 5.
Bad foot-contact:
clean scale or feet or check
for sufficient skin moisture.
6. If skin is too dry – moisten
feet or carry out measurement
after taking a bath or shower.
Interference with radio
contact between scales and
operator terminal.
The range of the radio signal
and correct operation are
dependent on several factors:
Battery condition, location
and position, screening
objects, other devices on the
same frequency band.
Under the environment with
electrostatic discharge, the
‘Body Balance Comfort F5’
could not maintain communi-
cation link and require the
user to take off the battery
and insert it again.
Under the environment with
radio interference the ‘Body
Balance Comfort F5’ could
not maintain communication
link and resume to normal
when the interference stops.
Technical data
Weighing capacity x graduation = max. 150kg x 100g
Display resolution: body fat: 0.1%
Display resolution: body water: 0.1%
Display resolution: muscle mass: 0.1%
Display resolution: energy consumption: 1 kcal
height: 100–250 cm
age: 10–99 years
8-person individual memory locations
Size of LCD screen
measuring circuit: 0.035 mA RMS, 50 kHz
Radio frequency: 433 MHz, range: 3m
Batteries: 4 x 1,5V AA for the scales
3 x 1,5 V AA for the operator terminal
Batteries supplied with unit.