Specifications

V1.98 21/06/06

 

 

20.2SPECIFICATIONS

20.2.1CONSOLE

• Supply Voltage

12.5 - 16 volts Negative earth system.

The Spray ECU’s power leads must be connected directly to the tractors battery terminals.

No attempt should be made to connect the system to positive earth vehicle. Damage will result and Warranty will become void.

• Supply Current Console

0.9 amps approxImately.

Maximum Solenoid supply current

2 Amps each

Maximum Electric Regulator Valve Motor Current: approx. 250milli-amps

20.2.2 GROUND SPEED, FAN SPEED AND AUXILIARY SHAFT SENSORS

Ground Speed Sensor,:

Hall effect type sensors

Fan Speed Sensor and

3 pin weather-pak plug (Pin A, B and C)

Auxiliary Shaft Sensors:

 

Sensor to Magnet Distance

2-3 millimeters (mm)

Supply Voltage

Supply 12 volts from Spray ECU

Signal Voltage:

4 -5- volts sensor inactive

 

< 1 volt sensor activated by magnet

20.2.3FLOW SENSORS Reed Switch Type (Broadacre)

• With Switch OFF:

Open Circuit

• Switch ON Resistance:

1800 Ohms

2 Wire Only

Maximum contact Current: 50 milli amps

• Accuracy:

2% in range 10% to 200% of nominal flow

• Bore:

15mm

• Nominal Flow Rate:

80l/min

• Calibration:

45.7 pulse/l

Page 104

Page 104
Image 104
Topcom X20 manual Ground Speed Sensor, Fan Speed Sensor, Auxiliary Shaft Sensors Sensor to Magnet Distance, Signal Voltage