Connecting the Spray ECU to the Battery

V1.98 21/06/06

 

 

Step 5: Connecting the Spray ECU to the Battery

1.DO NOT attach the wires to the battery terminals until the installation of the Tractor Harness, Sprayer Harness and Valve Harness has been completed.

2.Connect the Power/Comms Harness directly to 12 VDC battery terminals. Refer to Figure 14.

For tractors that use 24 Volt batteries you MUST use a 12 Volt / 15 Amp (minimum) inverter.

Figure 14: Battery Configuration

3.Do not connect the Power/Comms Harness to an alternator or starter motor as this may cause interference or power fluctuations or surges and may damage your system.

4.Attached the Red wire to the POSITIVE (+) battery terminal. Attach the Black wire to the NEGATIVE (-) battery terminal, when installation of the sprayer is completed.

5.DO NOT connect the Black wire to vehicle chassis unless an Isolation Switch is fitted to the negative side of the battery.

6.Do not power other equipment from the power cable; other than KEE products.

7.Connection to the battery terminals must be kept clean and tight at all times.

8.The hardware installation of the Sprayer Hardware Kit is now complete.

9.Refer to the ‘Getting Started’ (Section 2.0) and ‘Software Setup’ (Section 3.0) sections of this manual to complete the software setup for the Sprayer.