Setup Options -Switches

V1.98 21/06/06

 

 

8.2Custom Section Mapping

Figure 38: Custom Section Mapping

As the current Sprayer switchbox has only 6 switches available, and the ‘Spray ECU‘ can control up to 30 sections. The ‘Custom Section Mapping’ provides a method of operating several sections from each switch. The specific requirements will vary between operators and this window allows the operator to set which section switches operate which section valves.

The above example shows a 14 section dual line system, with section 15 controlling the second line. The first 3 sections are operated by Switch 1, sections (4,5 and 6) are operated by Switch 2 etc; with the second line being controlled from Switch 6 through the control circuit for section 1.

By touching the screen put an ‘X’ in the box, touching the same box again will remove the ‘X’ from the box. Any configuration is possible, simply by putting an ‘X’ in the box that is common to the switch required and the section to be controlled.

This selection does not effect the Auto Section Control (ASC) operation or the ‘Low Speed Shutoff’ settings for a particular boom section.

USE PRESETS

Selecting the ‘USE PRESET’ button uses a formula depending on how many Sections are selected and automatically sets which Section switches control which section valves.

UNDO

Selecting the ‘UNDO’ button, will undo, one change at a time. The ‘UNDO’ button can be selected several times to go back several steps, the ‘UNDO’ can be selected until the ‘UNDO’ button is greyed out, this means the configuration is the same as when the window was opened.

Selecting the ‘CANCEL’ button closes the ‘Custom Section Mapping’ window without saving. Select the ‘OK’ button once the Section Mapping configuration is finalised, selecting the ‘OK’ button closes the ‘Custom Section Mapping’ window and saves the changes.

Page 63

Page 63
Image 63
Topcom X20 manual Custom Section Mapping, USE Presets, Undo