Getting Started

V1.98 21/06/06

 

 

Major Topic Heading

Overview of Functions- The ‘Working Screen’

‘PUMP is ON’- button only appears when ‘Spray ECU’, ‘Prop. Valve’ and ‘Enable Pump Control Button’ are all selected. When selected the button says ‘PUMP is ON’ and turns ‘green’, this switches the hydraulic pump ON. When selected again the button says ‘PUMP is OFF’ and turns ‘red’, this switches the hydraulic pump OFF.

Ground Speed- Displays the actual ground speed whether from the wheel sensor on the sprayer, tractor radar or GPS speed; depending what type was selected.

Selecting the ‘Ground Speed’ readout displays a ‘SPEED’ screen on the right hand side. See Section 14.5 for details.

Sub Total (Area)- readout displays the area sprayed for the sub area selected depending on the units selected. The number in the top left hand side of the readout, is displaying the current sub area number. There are 10 sub area numbers (0 -9).

Selecting the ‘Sub Area’ readout displays an ‘AREA’ screen on the right hand side. See Section 14.6 for details.

Sub Total (Volume Used)- readout displays the volume (or weight) sprayed for the sub area selected depending on the units selected. The number in the top left hand side of the readout, is displaying the current sub area number. There are 10 sub area numbers (0 -9).

Selecting the ‘Sub Area’ readout displays a ‘AREA’ screen on the right hand side. See Section 11.6 for details.

Tank Indicator- Only appears when more than ‘1’ Tank is selected in OPTIONS/SPRAYER. This allows the ‘Sub Total Area’ and ‘Sub Total Volume’ to be displayed for each tank. To change which tank is displayed select either the ‘Sub Total Area’ readout or ‘Sub Total Volume’ readout, you will notice the ‘orange’ ‘Tank Indicator’ will change each time the readouts are selected, this will then display the readouts for each tank.

Pump Speed Readout- This displays the actual pump speed. The Pump Speed readout is only displayed if selected. See ‘Pump Options’ on the OPTIONS/ SETUP Page.

‘Min. Flow’ or ‘Min. Nozzle Flow’ indicator- A ‘red’ indicator will be displayed in the ‘Volume’ readout when the minimum flow for the regulator valve is reached or the minimum flow for the nozzles has been reached. Select the ‘Volume’ readout to see the reason the red indicator is being displayed. This will be displayed on the right hand ‘Flow’ window.

Page 37

Page 37
Image 37
Topcom X20 manual Getting Started V1.98 21/06/06 Major Topic Heading