2.3 Power Supply Troubleshooting

2 Troubleshooting Procedures

 

‰ 1R8-B1V output

 

 

 

 

 

 

 

 

 

 

 

Error code

 

Meaning

 

 

 

 

 

 

 

 

80h

1R8-B1V voltage is over 2.16V when the computer is powered on/off.

 

 

 

 

 

 

 

 

81h

1R8-B1V voltage is under 1.53V when the computer is powered on.

 

 

 

 

 

 

 

 

82h

1R8-B1V voltage is under 1.53V when the computer is booting up.

 

 

 

 

 

 

 

 

84h

1R8-B1V voltage is under 1.53V when BV power is maintained.

 

 

 

 

 

 

 

‰ PPV output

 

 

 

 

 

 

 

 

 

 

 

Error code

 

Meaning

 

 

 

 

 

 

 

 

90h

PPV voltage is over 1.80V when the computer is powered on/off.

 

 

 

 

 

 

 

 

91h

PPV voltage is under 0.32V when the computer is powered on.

 

 

 

 

 

 

 

 

92h

PPV voltage is under 0.32V when the computer is booting up.

 

 

 

 

 

 

‰ PTV output

 

 

 

 

 

 

 

 

 

 

 

Error code

 

Meaning

 

 

 

 

 

 

 

 

A0h

PTV voltage is over 1.26V when the computer is powered on/off.

 

 

 

 

 

 

 

 

A1h

PTV voltage is under 0.89V when the computer is powered on.

 

 

 

 

 

 

 

 

A2h

PTV voltage is under 0.89V when the computer is booting up.

 

 

 

 

 

 

‰ 1R5-E1V output

 

 

 

 

 

 

 

 

 

 

 

Error code

 

Meaning

 

 

 

 

 

 

 

 

B0h

1R5-E1V voltage is over 1.80V when the computer is powered on/off.

 

 

 

 

 

 

 

 

B1h

1R5-E1V voltage is under 1.275V when the computer is powered on.

 

 

 

 

 

 

 

 

B2h

1R5-E1V voltage is under 1.275V when the computer is booting up.

 

 

 

 

 

 

 

 

B3h

1R5-E1V voltage is under 1.275V when EV power is maintained.

 

 

 

 

 

 

 

PORTÉGÉ M500 Maintenance Manual (960-559)

[CONFIDENTIAL]

2-13

Page 55
Image 55
Toshiba SATELLITE U200 manual ‰ 1R8-B1V output