2.3 Power Supply Troubleshooting | 2 Troubleshooting Procedures |
| ||
Compare the patterns in the hexadecimal error code to the tables below. |
| |||
AC Adaptor |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 10h | AC Adaptor output voltage is over 16.5V. |
| |
|
|
|
| |
| 11h | CommonDock voltage is over 16.5V. |
| |
|
|
|
| |
| 12h | Current from the DC power supply is over 7.00A. |
| |
|
|
|
| |
| 13h | Current from the DC power supply is over 0.5A when there is no load. |
| |
|
|
|
| |
| 14h | Correction value of 0[A] is out of designed value. |
| |
|
|
|
|
|
1st Battery |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 22h | 1st battery discharge current over 0.5A when there is no load. |
| |
|
|
|
| |
| 23h | 1st battery charge current is over 3.9A in charging. |
| |
|
|
|
| |
| 24h | Correction value of 0[A] is out of designed value. |
| |
|
|
|
| |
| 25h | 1st battery charge current is over 0.3A in not charging. |
| |
|
|
|
|
|
2nd Battery |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 32h | 2nd battery discharge current is over 0.5A when there is no load. |
| |
|
|
|
| |
| 33h | 2nd battery charge current is over 3.9A in charging. |
| |
|
|
|
| |
| 34h | Correction value of 0[A] is out of designed value. |
| |
|
|
|
| |
| 35h | 2nd battery charge current is over 0.3A in not charging. |
| |
|
|
|
|
|
PORTÉGÉ M500 Maintenance Manual | [CONFIDENTIAL] |