STATus Subsystem
STATus:OPERation:VXIMonitor:CONDition?
Queries the contents of the VXI Monitor Condition register. A value of one in a bit indicates the corresponding condition bit has transitioned from false to true. Unused bits always return a value of zero. Definition of the bits in this register can be found in STATus:OPERation:VXIMonitor command.
There is no command associated with this query.
Syntax | STTusOPERationVXIMonitorCONDition | ||
Parameters |
|
|
|
Parameter |
| Query response | |
| Not applicable | <NR1> | |
Reset Value |
|
| |
Not Applicable |
| ||
Errors and Events | None |
|
|
Dependencies | None |
|
|
Examples | Query: | STTOPERVXIMCOND |
|
| Response: | 0 |
|
Related Commands STATus:OPERation:VXIMonitor?
STATus:OPERation:VXIMonitor:ENABle
3±46 | VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual |