STATus Subsystem

STATus:OPERation:VXIMonitor:SYSFail?

Queries the time when the VXI SYSFAIL signal was asserted. The time is relative to the mainframe power-on time.

If there are multiple occurrences of the VXI SYSFAIL signal, only the time of the first assertion is saved. Reading the time enables it to record the next SYSFAIL signal assertion time.

When no SYSFAIL is detected, the query returns a value of 0 in all fields. At power-on, or after restarting VXIMonitor the values of all fields are set to 0.

There is no command associated with this query.

Syntax STATus:￿P￿Ration:VXIMonitor:SYSFail?

Parameters

Parameter

 

Query response

 

Not Applicable

<Hour>,<Minute>,<Second>

Reset Value

 

 

 

0

 

 

Errors and Events

None

 

 

Dependencies

None

 

 

Examples

Query:

STAT:￿P￿R:VXIM:SYSF?

 

 

Response:

12,3,1

 

Related Commands STATus:OPERation:VXIMonitor:CONDition?

STATus:OPERation:VXIMonitor:ENABle

STATus:OPERation:VXIMonitor?

3±48

VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual