STATus Subsystem

STATus:QUEStionable:TEMPerature:CMAXimum?

Queries the current maximum measurable temperatures in the mainframe since power on. The returned value is in °C.

There is no command associated with this query.

Syntax STATus:QUEStion￿ble:TEMPer￿ture:CMAXimum? <Loc￿tion>

Parameters

<Location>

 

Query response

 

{AMBient OUT0 . . . OUT12 DELTa0 . . .

<NR1>

 

DELTa12}

 

 

 

AMBient ± ambient input temperature

 

 

OUT0 . . . OUT12 ± output temperature of

 

 

each slot

 

 

 

DELTa0 . . . DELTa12 ± output temperature

 

 

minus input temperature of each slot

 

Reset Value

 

 

 

0

 

 

Errors and Events

±224, ªIllegal Parameter Valueº

 

 

You attempted to use an illegal parameter value.

Dependencies

None

 

 

Examples

Query:

STAT:QUES:TEMP:CMAX? DELTA12

 

Response:

50

 

Related Commands STATus:QUEStionable:TEMPerature:LEVel?

STATus:QUEStionable:TEMPerature:MAXimum?

VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual