STATus Subsystem

STATus:QUEStionable:TEMPerature:LIMit

STATus:QUEStionable:TEMPerature:LIMit?

Sets or queries the maximum allowable ambient and delta temperatures in each slot. The factory default settings are 55 °C for ambient and 10 °C for each delta temperature.

Syntax

STATus:QUESt￿onab￿￿:TEMP￿ratur￿:LIM￿t <Locat￿on>,<L￿m￿t>

 

STATus:QUESt￿onab￿￿:TEMP￿ratur￿:LIM￿t? <Locat￿on>

 

 

 

 

 

 

 

<Location>

 

Query response

 

 

 

 

 

 

{AMBient DELTa0 . . . DELTa12}

<NR1>

 

 

AMBient - ambient input temperature

 

 

 

DELTa0 . . . DELTa12 ± output temperature minus

 

 

 

input temperature of each slot

 

 

 

 

 

 

 

 

<Limit>

 

 

 

 

 

 

 

 

 

<NRf>

 

 

 

 

If Location is AMBient

 

 

 

1 Limit 75

1

 

 

MIN

 

 

 

MAX

 

75

 

 

If Location is DELTan

 

 

 

5 Limit 30

5

 

 

MIN

 

 

 

MAX

 

30

Reset Value

 

 

 

 

0

 

 

Errors and Events

 

±224, ªIllegal Parameter Valueº

 

 

 

You attempted to set the location to an illegal value.

 

 

±222, ªData Out of Rangeº

 

 

 

You attempted to set the temperature limit to an illegal value.

Dependencies

 

None

 

 

Examples

 

Query:

STAT:QUES:TEMP:LIM? AMB

 

 

 

Response:

32

 

Related Commands STATus:QUEStionable:TEMPerature?

STATus:QUEStionable:TEMPerature:CONDition?

STATus:QUEStionable:TEMPerature:ENABle

STATus:QUEStionable:TEMPerature:LEVel?

VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual