STATus Subsystem
STATus:SEVent?
Returns the summary information on the power supply voltage events, temperature events, blower events, filter events, and VXI monitor events.
A one in a bit indicates the corresponding event has been asserted. Unused bits always return a value of zero. The query returns a value of zero at power on or when you send the *CLS command. Reading events by this command does not clear the events. Reading the specific event register will clear the corresponding bits in the register. (That is, STAT:QUES:VOLT? will clear all of the voltage bits in this register). Summary information for current, power, triggers and IRQ reside in an overflow register. If bit 30 is set, the overflow register should be queried for more information. See the STATus:S2EVent? query on page 3±108.
There is no command associated with this query.
Syntax STATus:SEVent?
Parameters | Parameter | Query response |
| Not applicable | <NR1> |
|
|
|
Event status word bits | Definition |
|
|
D0 | Blower 1 |
|
|
D1 | Blower 2 |
|
|
D2 | Filter |
|
|
D3 | Slot 0 Delta Temperature |
|
|
D4 | Slot 1 Delta Temperature |
|
|
D5 | Slot 2 Delta Temperature |
|
|
D6 | Slot 3 Delta Temperature |
|
|
D7 | Slot 4 Delta Temperature |
|
|
D8 | Slot 5 Delta Temperature |
|
|
D9 | Slot 6 Delta Temperature |
|
|
D10 | Slot 7 Delta Temperature |
|
|
D11 | Slot 8 Delta Temperature |
|
|
D12 | Slot 9 Delta Temperature |
|
|
D13 | Slot 10 Delta Temperature |
|
|
D14 | Slot 11 Delta Temperature |
|
|
D15 | Slot 12 Delta Temperature |
|
|
3±106 | VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual |