STATus Subsystem

STATus:SEVent?

Returns the summary information on the power supply voltage events, temperature events, blower events, filter events, and VXI monitor events.

A one in a bit indicates the corresponding event has been asserted. Unused bits always return a value of zero. The query returns a value of zero at power on or when you send the *CLS command. Reading events by this command does not clear the events. Reading the specific event register will clear the corresponding bits in the register. (That is, STAT:QUES:VOLT? will clear all of the voltage bits in this register). Summary information for current, power, triggers and IRQ reside in an overflow register. If bit 30 is set, the overflow register should be queried for more information. See the STATus:S2EVent? query on page 3±108.

There is no command associated with this query.

Syntax STATus:SEVent?

Parameters

Parameter

Query response

 

Not applicable

<NR1>

 

 

 

Event status word bits

Definition

 

 

D0

Blower 1

 

 

D1

Blower 2

 

 

D2

Filter

 

 

D3

Slot 0 Delta Temperature

 

 

D4

Slot 1 Delta Temperature

 

 

D5

Slot 2 Delta Temperature

 

 

D6

Slot 3 Delta Temperature

 

 

D7

Slot 4 Delta Temperature

 

 

D8

Slot 5 Delta Temperature

 

 

D9

Slot 6 Delta Temperature

 

 

D10

Slot 7 Delta Temperature

 

 

D11

Slot 8 Delta Temperature

 

 

D12

Slot 9 Delta Temperature

 

 

D13

Slot 10 Delta Temperature

 

 

D14

Slot 11 Delta Temperature

 

 

D15

Slot 12 Delta Temperature

 

 

3±106

VX1410A & VX1420A IntelliFrame Mainframe Instruction Manual